Smart Veterinary Monitors

Model : RN PET H5

Display screen : 5.5inch

Resolution : 1280*720 pixels

Type : Rechargeable lithium battery 4000 mAh 3.7V

Maximum charging time is less than 6 hours

Working time : 6 hours

Voltage : DC 5V 2A

Product Description Support OEM, reliable performance, cost-effective multi-parameter monitor solution

Features

  • 5.5inch capacitive touch screen with friend Ul design
  • Suitable for small and large animals
  • Anti-defibrillator, anti-ESU , with Titration function
  • Advanced blood oxygen technology, anti-motion interference
  • Smart system with built-in manual
  • Multiple configurations to choose:
    WSpet H5:SPO2+NIBP+TEMP
    wSpet H5S:SPO2
    WSpet H5ST:SPO2+TEMP
    WSpet H5N:NIBP+TEMP
    WSpet H5P:SPO2+NIBP+ECG+TEMP
  • Optional: Wifi , wireless printer, Etco2 , carry bag
  • Remote data transfer available, supporting to lOS/Android system (App)
  • Rechargeable lion-battery backup time more than 6 hours continuously working
  • Ultra-thin design, lightweight,compact easy to carry

Technology specifications

Product name RN PET H5
Temperature Technique: Thermistor probe (2.25K/10k);
Measuring and Alarm Range: 0.0℃~50℃;
Unit: Celsius (℃);
Resolution: 0.1℃ or 1F;
Accuracy: ±0.1℃ (exclusive probe);
Pulse Rate Measuring and Alarm Range: 25~250bpm;
Accuracy: ±3bpm;
Resolution: 1bpm;
ECG Lead mode: 3 Leads I,II,III;
Gain: 1/4 file (X0.25) 2.5mm/mV; 1/2 file (X0.50) 5.0mm/mV; 1 file (X1) 10mm/mV; 2 files (X2) 20mm/mV;
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s;
Baseline Recovery: < 3s after defibrillation (Monitor mode), < 1s after defibrillation (Surgery mode);
Bandwidth: Diagnostic 0.05~100, Monitor 0.5~40Hz, Surgery 1~20Hz;
NIBP Method: Pulse wave oscillation method;
Measure mode: Manual, Auto, Continue;
Measure interval in auto mode: 1 file (X1) 10mm/mV; 2 files (X2) 20mm/mV; 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480min;
STAT mode cycle time: Keep 5 minutes;

Measure and Alarm Range:

Large Animal: SYS 30~280mmHg DIA 10~220mmHg MEAN 20~240mmHg,

Small Animal: SYS 30~220mmHg DIA 10~160mmHg MEAN 20~170mmHg,

Static pressure range: 0~300mmHg,

Static pressure accuracy: 3mmHg;

Maximum Mean error: 5mmHg;
Maximum Standard deviation: 8mmHg;
Static pressure accuracy: ±3mmHg;
Resolution: 1mmHg;
Accuracy: Maximum Mean error ± 5mmHg, Maximum Standard deviation<8mmHg;
Over pressure Protection: Large animal~300mmHg, Small animal~240mmHg;
Heart Rate Measure range: Large animal 15~300 bpm, Small animal 15~350 bpm;
Accuracy: 1% or 1bpm, whichever is greater;
Resolution: 1 bpm;
SpO2 Measurement Range: 0~100%;
Resolution: 1%;
Response Modes: Low, Medium, High;
Accuracy: 70%~100%: 2% <69%: unspecified;
EtCO2 Measure method: Non-dispersive infrared (NDIR);
Measure Range: 0~19.7% (0~150mmHg) 0~20kPa;
Resolution: 0.1 mmHg;

CO2 Accuracy: 0~40 mmHg, ±2 mmHg, 41~70 mmHg, ±5% of reading, 71~100 mmHg, ±8% of reading, 101~150 mmHg,

±10% of reading, at 760mmHg, ambient temperature of 25℃);

Respiratory Rate: Range:3-150BrPM, Accuracy:±1bpm;
Transportation and Storage Temperature: -20~50℃;
Humidity: 10%~90%(non-condensing);
Atmosphere pressure: 86KPa~106KPa;
Respiration Method:lmpedance between RA-LL;
Gain: x0.25, x0.50, x1, x2, x4;
Respiration Rate:0~120/0-150BrPM;
Sweep speed: 6.25 mm/s,12.5 mm/s,25mm/s;
Resolution:1 BrPM;
Apnea Alarm:10~40s;
Measure range: Large animal: 0-120 bpm;
Small animal:0-150 bpm;
Trend & Reviewing NlBP measurement reviewing: 1500groups;
Waveform review: 3 hours 600groups;
Alarm event: 1000 groups of parameter alarms events and associated parameter;